Blueprint QA Checklist for California Commercial TI — Free Download

Get your plans permit-ready, faster. We built a Blueprint QA Checklist specifically for California commercial tenant improvements, so your drawings clear plan check and field coordination with fewer RFIs and change orders.

DOWNLOAD #DOITRIGHT-BP.PDF

Who IS it for

  • General contractors & estimators aligning scope, assumptions, and add/alt pricing

  • Architects & designers sanity-checking code, accessibility, and coordination before submittal

  • MEP & FP subs verifying details that affect installation and inspections

  • Owners/PMs looking for predictable approvals and fewer surprises

What’s inside

  • Admin/Cover — code editions, occupancy & construction type, deferred submittals, special inspections (CBC Ch. 17)

  • Life Safety — egress calcs, rated assemblies, UL details, exit/emergency lighting & signage

  • Path of Travel — accessible route from public way/parking; curb ramps and striping notes

  • Demo/Phasing — clear scope, occupied conditions, egress during construction, hazmat notes

  • Architectural — dimensioned plans, RCPs, millwork details, door/hardware schedules, ADA elevations

  • Structural — openings, slab cuts/infills, anchors (ICC-ESR), epoxy with special inspection, seismic bracing

  • Mechanical — O/A and DCV, economizers, duct/fire-smoke dampers, control sequences, Title 24 ties

  • Plumbing — DWV/water/gas risers, fixture counts, interceptors, backflow, ADA clearances

  • Electrical/FA/LV — one-line, load calcs, lighting zones, UL 924 for EM, FA riser and sequence

  • Fire Protection & Hoods — sprinkler scope (or deferred), hood interlocks and clearances

  • Title 24 (Part 6) — NRCC in set; NRCI/NRCA deliverables; daylighting zones; acceptance testing

  • Accessibility (ADA/CBC 11B) — POT 20% worksheet; door/thresholds; restroom & counter dims; signage

  • Health Dept (if food service) — NSF fixtures, indirect waste, finishes, hoods & MUA

  • Coordination & QC — clash checks, explicit ADA dims, headroom & protrusions, load data for anchorage

  • Submittal Package — portal checklists, bookmarked PDFs, contacts, licenses, and required worksheets

How to use it

  1. Pre-submittal: run the checklist across A/E/GC/MEP sheets; plug gaps before plan check.

  2. Plan check: include Title 24 NRCC, POT (20%) allocation reference, and any AHJ checklists.

  3. Construction: hand the checklist to field supers for quick verifications on doors, ADA clearances, anchors, and controls.

  4. Closeout: keep photos + dims in your as-builts; match acceptance/testing forms to what’s on drawings.

FAQ

Does this replace an architect’s or engineer’s code analysis?

No—it’s a practical QA tool to reduce misses and streamline approvals.

Is it specific to California?

Yes—geared to CBC, ADA/CBC 11B, Title 24 (Part 6), and common AHJ expectations for commercial TI.

Can I share it with subs?

Please do. It works best when designers, GC, and subs review the same list.